SAYFA Product Brochure Icon  SAYFA icon for fall protection and height safety product drawingsSAYFA icon for fall protection and height safety imagesSAYFA icon for fall protection and height safety product install manuals SAYFA icon for fall protection and height safety product operation manualsSAYFA icon for SAYFA products in revit modelsSAYFA icon for fall protection and height safety videosWarranty and Certs icon

XPLORA Eyebolt Assembly, M16
  • Includes washer, spring washer and nut
NOTE
MATERIALS
  • Eyelet – stainless steel (316)
  • Concrete insert – stainless steel (316)
DIMENSIONS
  • Eyebolt – M14 / 25mm
  • Eyelet ID – 35mm
  • Concrete insert – drilled hole diameter / 28mm
  • Concrete insert – drilled hole depth / 105mm
  • Minimum concrete thickness – 150mm
  • Minimum concrete edge distance – 200mm
  • Minimum anchor spacing – 200mm
  • Minimum concrete strength – 20MPa
WEIGHT
  • 0.5kg (includes eyebolt and insert)
WORKING LOAD LIMIT
  • Recommended for single person use – 15kN rated
  • Rope access use – 12kN
  • Fall arrest use- 15kN
  • Concrete structure integrity, suitability and anchor location to be assessed and determined by a competent person prior to installation
  • Anchor is to be used in a shear load direction only (pulled at an angle not exceeding 20o to the installed surface)
  • No tensile loading for fall arrest or rope access recommended as per requirements of Standard AS/NZS 1891.4:2009
  • XPLORA AP127.10 Concrete Mount Anchor must be used in conjunction with an approved harness and lanyard system incorporating an energy absorber where required
COMPLIANCE

XPLORA AP127.10 Concrete Mount Anchor is designed and manufactured generally in accordance with requirements of Standards AS/NZS 1891.4:2009, AS/NZS 4488.2:1997 and AS/NZS 5532:2013.

PRODUCT WARRANTY

10 years from date of purchase subject to correct installation, use and maintenance in accordance with manufacturer’s specifications and recommendations.

INSPECTION AND MAINTENANCE

This device requires periodic inspection and maintenance by a qualified safety inspector. See load testing note below.

IMPORTANT NOTE

Minimum thickness of concrete – 150mm. Thickness less than 150mm requires compliance by having structure certified and the anchor proof load tested as per AS/NZS 1891.4:2009.

Device is for personnel use only.